Show simple item record

dc.contributor.authorAttanayake, Upul
dc.contributor.authorAmunugama, Harsha
dc.contributor.authorICASP14
dc.date.accessioned2023-08-03T13:35:40Z
dc.date.available2023-08-03T13:35:40Z
dc.date.issued2023
dc.identifier.citationHarsha Amunugama, Upul Attanayake, Redundancy Analysis of Unbraced Network Arch Bridges, 14th International Conference on Applications of Statistics and Probability in Civil Engineering (ICASP14), Dublin, Ireland, 2023.
dc.descriptionPUBLISHED
dc.description.abstractThe redundancy of a structural system is its ability to support loads even after a failure of one or several structural components. Redundancy analysis is vital to assess the safety and reliability of network arch bridges, particularly in the context of extreme events such as hanger replacement and hanger loss. Even though the Post-Tension Institute (PTI) offers specific design guidelines on handling abrupt cable loss and replacement for cable-stayed bridges, it failed to address the issue of gradual collapse comprehensively. However, comparable guidelines are lacking in the AASHTO design practices. While system factors for simple bridge systems have been extensively investigated, there is a lack of research on corresponding system factors for complex structures such as network arch bridges. Recently, an attempt was made to establish a step-by-step procedure to compute the system factors for a steel box tied arch bridge structure system. However, no studies were found to determine the system factors for freestanding network arch bridges. The lack of research or documentation outlining a specific methodology to establish the system factors for unbraced network arch bridges underscores the need for further research to establish design standards that prioritize the safety and resilience extreme circumstances. To address this knowledge gap, a parametric investigation is currently being conducted to develop a definitive procedure for determining the system factors for straight and moderately skew (skew<20ᄚ) unbraced network arch bridges using finite element analysis (FEA). A 265 ft long, 96.5 ft wide, and 18ᄚ skew unbraced network arch bridge constructed in Detroit, Michigan, was used as the prototype and evaluated its performance during the hanger replacement scenario under dead load conditions. The results of the analysis indicate that the sequential replacement of hangers in a straight and moderately skew unbraced network arch bridges can be performed under its own weight without impacting the structural integrity.
dc.language.isoen
dc.relation.ispartofseries14th International Conference on Applications of Statistics and Probability in Civil Engineering(ICASP14)
dc.rightsY
dc.titleRedundancy Analysis of Unbraced Network Arch Bridges
dc.title.alternative14th International Conference on Applications of Statistics and Probability in Civil Engineering(ICASP14)
dc.typeConference Paper
dc.type.supercollectionscholarly_publications
dc.type.supercollectionrefereed_publications
dc.rights.ecaccessrightsopenAccess
dc.identifier.urihttp://hdl.handle.net/2262/103412


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

  • ICASP14
    14th International Conference on Application of Statistics and Probability in Civil Engineering

Show simple item record