dc.identifier.citationWetterling, F, Högler, M, Molkenthin, U, Junge, S, Gallagher, L, Macrae, IM, Fagan, AJ, The design of a double-tuned two-port surface resonator and its application to in vivo Hydrogen- and Sodium-MRI, JOURNAL OF MAGNETIC RESONANCE, 217, 2012, 10 - 18en
dc.identifier.otherYen
dc.descriptionPUBLISHEDen
dc.description.abstractThe design and construction of a two-port surface transceiver resonator for both 1H and 23Na-MRI in the rodent brain at 7T is described. Double-tuned resonators are required for accurately co-registering multi-nuclei data sets, especially when the time courses of 1H and 23Na signals are of interest as, for instance, when investigating the pathological progression of ischaemic stroke tissue in vivo. In the current study, a single element two port surface resonator was developed wherein both frequency components were measured with the same detector element but with each frequency signal routed along different output channels. This was achieved by using the null spot technique, allowing for optimal variable tuning and matching of each channel in situ within the MRI scanner. The 23Na signal to noise ratio, measured in the ventricles of the rat brain, was increased by a factor of four compared to recent state-of-the-art rat brain studies reported in the literature. The resonator?s performance was demonstrated in an in vivo rodent stroke model, where regional variations in 1H apparent diffusion coefficient maps and the 23Na signal were recorded in an interleaved fashion as a function of time in the acute phase of the stroke without having to exchange, re-adjust, or re-connect resonators between scans. Using the practical construction steps described in this paper, this coil design.en
dc.description.sponsorshipScience Foundation Ireland (06/RFP/PHY006)en
dc.format.extent10en
dc.format.extent18en
dc.language.isoenen
dc.relation.ispartofseriesJOURNAL OF MAGNETIC RESONANCEen
dc.relation.ispartofseries217en
dc.rightsYen
dc.subject23Na-MRIen
dc.subjectDouble-Tuningen
dc.subjectTwo-Port Surface Resonatoren
dc.subjectcoil constructionen
dc.titleThe design of a double-tuned two-port surface resonator and its application to in vivo Hydrogen- and Sodium-MRIen
dc.typeJournal Articleen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/fagananen
dc.identifier.rssinternalid77927en
dc.subject.TCDThemeNeuroscienceen
dc.subject.TCDThemeNext Generation Medical Devicesen
dc.identifier.rssurihttp://dx.doi.org/10.1016/j.jmr.2012.02.002en
dc.contributor.sponsorScience Foundation Ireland (SFI)en
dc.contributor.sponsorGrantNumber06/RFP/PHY006en
dc.identifier.urihttp://hdl.handle.net/2262/63921


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record