dc.identifier.citationSeheult, JN, O'Connell, P, Tee, KC, Bholah, T, Al Bannai, H, Sulaiman, I, MacHale, E, D'Arcy, S, Holmes, MS, Bergin, D, Reeves, E, Reilly, RB, Crispino-O'Connell, G, Ehrhardt, C, Healy, AM, Costello, RW, The Acoustic Features of Inhalation can be Used to Quantify Aerosol Delivery from a Diskus (TM) Dry Powder Inhaler, PHARMACEUTICAL RESEARCH, 31, 10, 2014, 2735-2747en
dc.identifier.issn0724-8741en
dc.identifier.otherYen
dc.descriptionPUBLISHEDen
dc.description.abstractPurpose Some patients are unable to generate the peak inspiratory flow rate (PIFR) necessary to de-agglomerate drug particles from dry powder inhalers (DPIs). In this study we tested the hypothesis that the acoustic parameters of an inhalation are related to the PIFR and hence reflect drug delivery. Methods A sensitivity analysis of the relationship of the acoustics of inhalation to simultaneously recorded airflow, in a cohort of volunteers (n = 92) was performed. The Next Generation Impactor (NGI) was used to assess in vitro drug delivery from salmeterol/fluticasone and salbutamol Diskus (TM) DPIs. Fine particle fraction, FPF, (<5 mu m) was measured at 30-90 l/min for 2-6 s and correlated with acoustically determined flow rate (IFRc). In pharmacokinetic studies using a salbutamol (200 mu g) Diskus (TM), volunteers inhaled either at maximal or minimal effort on separate days. Results PIFRc was correlated with spirometrically determined values (R-2=0.88). In in vitro studies, FPF increased as both flow rate and inhalation duration increased for the salmeterol/fluticasone Diskus (TM) (Adjusted R-2=0.95) and was proportional to flow rate only for the salbutamol Diskus T (Adjusted R-2=0.71). In pharmacokinetic studies, blood salbutamol levels measured at 20 min were significantly lower when PIFRc was less than 60 l/min, p<0.0001. Conclusion Acoustically-determined PIFR is a suitable method for estimating drug delivery and for monitoring inhalation technique over time.en
dc.format.extent2735-2747en
dc.relation.ispartofseriesPHARMACEUTICAL RESEARCHen
dc.relation.ispartofseries31en
dc.relation.ispartofseries10en
dc.rightsYen
dc.subjectInhalationen
dc.titleThe Acoustic Features of Inhalation can be Used to Quantify Aerosol Delivery from a Diskus (TM) Dry Powder Inhaleren
dc.typeJournal Articleen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/reillyrien
dc.identifier.rssinternalid100355en
dc.identifier.doihttp://dx.doi.org/10.1007/s11095-014-1371-xen
dc.rights.ecaccessrightsopenAccess
dc.identifier.orcid_id0000-0001-8578-1245en
dc.identifier.urihttp://hdl.handle.net/2262/75641


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record