Show simple item record

dc.contributorMarie Curie IAPP project NOTESen
dc.contributor.authorO'Kelly, Brendanen
dc.date.accessioned2013-08-08T13:14:09Z
dc.date.available2013-08-08T13:14:09Z
dc.date.created22 Feben
dc.date.issued2013en
dc.date.submitted2013en
dc.identifier.citationO'Kelly B.C., Sivakumar V. and Brinkgreve R.B.J., Uplift Resistance of Granular Anchors in Clay Under Undrained Condition, Invited presentation at the First Workshop on Soil-Structure Interaction, Trinity College Dublin, Dublin, 22 Feb, 2013, Marie Curie IAPP project NOTES, 9en
dc.identifier.otherNen
dc.descriptionPUBLISHEDen
dc.descriptionTrinity College Dublin, Dublinen
dc.description.abstractGranular anchors (GAs) are a relatively new concept in ground engineering and can be used to resist uplift/pullout forces and compressive forces in addition to the ground improvement provided. The GA consists of three main components: a base plate; tendon and compacted granular backfill. Under direct pullout loading, the vertical centrally-located tendon transmits the anchor load applied at the ground surface to the column base via the base plate, compressing the granular column, causing significant dilation of the granular material to occur, thereby forming the anchor. In this study, experimental field tests in intact lodgement till and numerical analysis were performed to investigate the load?displacement behaviour, modes of failure and ultimate pullout capacity of these anchors for the undrained (short-term) condition. The pullout capacity is increased by increasing the anchor surface area either by increasing the anchor length L and/or diameter D. The GAs displaced significantly under loading, with pullout failure generally occurring for anchor displacements of ? ~ D/2. The numerical analysis confirmed that the applied tension load was simultaneously resisted by localised bulging in the vicinity of the column base and by shaft resistance mobilised along the column length, with the dominant failure mode governed by the column L/D ratio. Short GAs (L/D < ~7) principally failed in shaft resistance whereas structural failure of the column occurred for deep GAs (L/D > 7) by localized end-bulging, concentrated over a length of approximately 2?3 D from the column base.en
dc.description.sponsorshipMarie Curie IAPP project NOTES (Grant No. PIAP-GA-2008-230663)en
dc.format.extent9en
dc.language.isoenen
dc.rightsYen
dc.subjectGround anchorsen
dc.subjectGranular anchorsen
dc.subjectUltimate capacityen
dc.subjectDublin Boulder Clayen
dc.titleUplift Resistance of Granular Anchors in Clay Under Undrained Conditionen
dc.title.alternativeInvited presentation at the First Workshop on Soil-Structure Interactionen
dc.typeInvited Talken
dc.type.supercollectionscholarly_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/bokellyen
dc.identifier.rssinternalid83352en
dc.identifier.rssurihttp://notesproject.webs.com/programme.htmen
dc.identifier.orcid_id0000-0002-1343-4428en
dc.contributor.sponsorMarie Curieen
dc.contributor.sponsorGrantNumberPIAP-GA-2008-230663en
dc.identifier.urihttp://hdl.handle.net/2262/66939


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record