Show simple item record

dc.contributor.authorKenny, Rose
dc.date.accessioned2019-08-21T15:25:21Z
dc.date.available2019-08-21T15:25:21Z
dc.date.issued2003
dc.date.submitted2003en
dc.identifier.citationArmstrong V.L., Lawson J., Kamper A.M., Newton J., Kenny R.A. The use of an implantable loop recorder in the investigation of unexplained syncope in older people, Age and Ageing, 2003, 32, 2, 185-188en
dc.identifier.otherY
dc.identifier.otherdoi: https://doi.org/10.1093/ageing/32.2.185
dc.descriptionPUBLISHEDen
dc.description.abstractIntroduction: Reveal is a patient activated implantable loop recorder device with an 18 month battery life now available to assist in the diagnosis of suspected syncope or arrhythmias. We present our experience using this device in older subjects referred to a dedicated falls and syncope clinic in whom usual clinical assessment had not satisfactorily identified an attributable diagnosis but where we still suspected a cardiovascular cause for syncope or falls. Methods and results: during the past 3 years 15 subjects (mean age 73 years, range 61–89 years) had Reveal implanted for symptoms of syncope alone (n=6; 40%) and unexplained falls (n=3; 20%) or symptoms of syncope and unexplained falls (n=6; 40%). Symptom duration was long (mean 48 months; range 4–200 months). Subjects had experienced significant morbidity, 6 subjects (40%) required A&E attendance or hospital admission and 4 (27%) experienced a fracture. Despite extensive and repeated investigations, which included 12-lead ECG, echocardiogram, 24-h ambulatory heart rate monitor, 24-h ambulatory blood pressure monitor, orthostatic blood pressure measurement, supine and erect carotid sinus massage, electroencephalogram, and passive and GTN head up tilt testing, the attributable diagnosis remained unexplained. Of the 15 subjects, 7 have activated the device at 4 (range0–14) months after implantation. Bradycardia was identified in 3 and ventricular tachycardia in 1 subject. Two subjects did not activate the device during the 18 months it was in-situ. Four people had problems with device activation. This is comparable to rates noted using Reveal in younger subjects. Conclusion: Reveal offers additional diagnostic yield in complex elderly subjects with suspected cardiovascular causes of syncope or unexplained falls which have not been previously satisfactorily diagnosed despite extensive investigationsen
dc.format.extent185en
dc.format.extent188en
dc.language.isoenen
dc.relation.ispartofseriesAGE AND AGEING;
dc.relation.ispartofseries32;
dc.relation.ispartofseries2;
dc.rightsYen
dc.subjectSyncopeen
dc.subjectImplantable loop recorderen
dc.subjectElderlyen
dc.subjectFallsen
dc.titleThe use of an implantable loop recorder in the investigation of unexplained syncope in older peopleen
dc.typeJournal Articleen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/rkenny
dc.identifier.rssinternalid39484
dc.rights.ecaccessrightsopenAccess
dc.subject.TCDThemeAgeingen
dc.identifier.urihttps://academic.oup.com/ageing/article/32/2/185/29040
dc.identifier.urihttp://hdl.handle.net/2262/89278


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record